110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

Shenzhen Zhong Jian South Environment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

Brand Name : ZJNF

Model Number : ZJNF-1

Certification : CE

Place of Origin : China

MOQ : 1

Price : negotiate

Payment Terms : tt lc PayPal credit card

Delivery Time : 18 days

Packaging Details : plywood/wooden package

Material : Acrylic plate/Aluminum

Air Volume : 1000-1200m³/h

Type : HEPA

Filter Efficiency : 99.99% 0.3um

Voltage : 110V/220V 50HZ/60HZ

Air Flow : Vertical/Horizontal

Contact Now

Here is the professional English translation of the layered ultra-clean workbench description:


Laminar Flow Clean Bench
A laminar flow clean bench utilizes a high-efficiency air filtration system to generate unidirectional airflow (vertical or horizontal), creating a localized high-cleanliness operating environment. Its core function is to protect samples from contamination. Key features and applications are as follows:

I. Core Principles & Structure

  1. Laminar Flow Mechanism
    Room air is pre-purified by a primary filter, pressurized into a plenum chamber via a blower, and then filtered through a HEPA filter to form stable unidirectional airflow (vertical or horizontal)
    • Vertical Laminar Flow‌: Top-down airflow prevents direct exposure to operators; ideal for high-risk biomedical applications
    • Horizontal Laminar Flow‌: Horizontal outward airflow offers larger workspace; commonly used in electronics
  2. Cleanliness Class
    Work zone achieves Class 100 (ISO Class 5) cleanliness: ≤3.52 particles (≥0.5μm) per liter
  3. Core Components
    Include primary/HEPA filters, blower, stainless steel work surface, UV germicidal lamp, and smart control system (e.g., touchscreen for wind speed adjustment)

II. Classification & Selection

Classification Basis Type Characteristics
Airflow Direction Vertical Laminar Flow Top-down airflow; high operator safety; suitable for biological labs
Horizontal Laminar Flow Larger workspace; lower noise; preferred in electronics
Operation Structure Single-person single-side Single blower; lower noise
Dual-person single-side Dual blowers; moderate noise increase
Dual-person dual-side Enables collaboration; requires larger space
Special Designs Recirculating Type No external ducts; flexible deployment in non-clean areas
Benchtop Type Space-saving; ideal for compact labs

III. Primary Applications

  • Biomedicine‌: Cell culture, vaccine preparation, aseptic preparation filling (contamination rate <0.8%)
  • Medical Testing‌: Virus isolation, nucleic acid detection (prevents aerosol contamination)
  • Precision Manufacturing‌: Electronic component assembly, optical instrument production (anti-dust/anti-static)
  • Food & Research‌: Microbial testing, gene editing (e.g., CRISPR), ensures experimental accuracy

IV. Operation & Maintenance Guidelines

  1. Environmental Requirements
    Temperature: 5–35°C; humidity ≤85%; avoid dusty/explosive environments
  2. Safe Operation
    • Sterilize with UV light for 30 mins before use; keep glass sash partially closed during operation
    • Regularly monitor wind speed (0.3–0.6m/s for vertical flow) and filter pressure differential
  3. Maintenance Cycle
    • Clean primary filter monthly; replace HEPA filter every 2–3 years (varies by environment)
    • Equipment lifespan correlates with air cleanliness; shorter intervals in tropical regions

V. Technology Evolution

Modern models (e.g., VD-650) feature smart controls for stepless wind speed adjustment and real-time pressure display; DC motors reduce energy consumption by 30%, while stainless steel enhances corrosion resistance. High-end units include dynamic airflow monitoring to limit speed fluctuations to ≤20%

Technical Data

MODEL ZJNF-1 ZJNF-2 ZJNF-3 ZJNF-4
Table Size(mm) 1200*600*740 1200*600*1500 600*600*740 1800*600*1460
Fan Size(mm) 1200*600*740 1175*575*320 575*575*320 1175*575*320
Material Aluminum / Stainless Steel
Efficiency 99.99% @ 0.3um

Product Details

110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter


Product Tags:

HEPA Filter Laminar Flow Clean Workbench

      

110V/220V Laminar Flow Clean Workbench

      

Acrylic Plate Laminar Flow Clean Workbench

      
Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter product

110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Zhong Jian South Environment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)